How to test the potted circuit breaker and potted module.

For Potted Modules shipped before August of 2012, you can test by applying power to the potted circuit breaker to and if good the following voltages will be seen:

  1. 23-24V DC on the green to orange wires continuously with or without load (with or without solenoid plugged in)
  2. No voltage on green to yellow after 300 millisecond

 There is no good way to check the inrush voltage on potted circuit breaker/ potted module.

For Potted Modules shipped after August 2012:

  1. 23-24.6V DC on the green to orange wires continuously with or without load (with or without solenoid plugged in)
  2. The pulling coil voltage between green and yellow wires measures 22.6VDC continuously without load
  3. The pulling coil voltage between green and yellow wires measures 0VDC continuously with load

 