How To Select Size Of Bar Coordinator?

To determine the size of the Ives COR bar coordinator, follow the steps below:

  1. Start with the active door width (X)
  2. Next identify the overall frame opening between stops (F) 
  3. Preferably, the coordinator will equal the active door width (X) + approximately 1/2 inactive door width (Y).
  4. The coordinator must be 6" longer than the active door width (X) and less than the overall frame opening between stop (F).
  5. Filler bar can be used to cover remaining space along header.  Can be cut to size in field.

 