How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?

To convert the Von Duprin 6000 series electric strikes from FS to FSE  or from FSE to FS follow these steps:

  1. Remove the electric strike face plate.
  2. Remove the strike box cover plate by removing the two screws.
  3. Remove the existing slider and replace it with one from the part list below.
  4. See the attached photos and installation instruction for reference. 
  5. 6000 FS/FSE Conversion Instructions
  6. 6211 photo with sliders


Part numbers:

  • FS slider, part # 090591  (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below)
     
  • FS slider, part #090798 (Use this slider for FS models 6211WF/6212WF/6221/6223 only)
     
  • FSE slider, part # 090798 (Use for all EXCEPT 6211WF/6212WF/6221/6223.  See 090591 below)
     
  • FSE slider, part # 090591  (Use this slider for FSE models 6211WF/6212WF/6221/6223 only)