The Von Duprin M996L lever ships Fail Safe by default.
If fail secure operation is needed for M996L, this can be completed in the field.
Follow These Steps: .
1. On the back of the M996L, toggle the small switch from the FS position to the FSE position. Click HERE for video.
2. Power cycle the trim in order for the change to take effect. *
* To power cycle the trim:
If the M996L is NOT connected to the Chexit, then temporarily connecting and removing trim power wires to 24VDC will power cycle the trim.
If the M996L IS connected to the Chexit, then present a valid credential connected to Chexit wiring. (Credential will be connected to the Chexit INH wires.) This will toggle power to the trim.
For reference, click HERE for M996L instructions.
Contact product support at 877-671-7011, option 2, for any questions.