300 Series mag lock (320, 350, and 390) control boards are no longer available. However, as long as the (DPS) or the magnetic bond sensor (MBS) features are not needed The circuit board can be bypassed to wire the magnet directly.
For 12 VDC operation both the RED and BLACK wires get connected to positive(+) and the BLUE and WHITE get connected to negative(-).
For 24 VDC operation the RED gets connected to positive(+), the WHITE gets connected to negative(-) and the BLACK and BLUE wires get tied together.