How does the RX switch operate with the Schlage L9000?

Consult the following table for RX operation details:
 

Category

Function

RX Switch Monitors

How is RX Switch activated?

Is RX switch handing field reversible?

Can RX switch be added in the field?

Electrified

L9090EL/EU

Inside lever only 

When the inside lever is rotated, the switch is activated thus changing state for the access control system.

Field Reversible

RX Switch can be added in the field

L9091EL/EU
L9092EL/EU
L9093EL/EU
L9095EL/EU
L9492EL/EU
L9493EL/EU
L9494EL/EU
L9495EL/EU

Electrified Vandlgard

LV9090EL/EU

Both inside and outside levers 

When the inside or outside lever is rotated, the switch is activated thus changing state for the access control system.

Not Field Reversible

Complete lock case has to be replaced to add RX

LV9091EL/EU
LV9092EL/EU
LV9093EL/EU
LV9095EL/EU
LV9492EL/EU
LV9493EL/EU
LV9494EL/EU
LV9495EL/EU

Discontinued Electrified

L9080EL/EU

Both inside and outside levers 

When the inside or outside lever is rotated, the switch is activated thus changing state for the access control system.

Not Field Reversible

Replace with L9092 lock case with RX

L9082EL/EU

Replace with L9095 lock case with RX