Consult the following table for RX operation details:
Category | Function | RX Switch Monitors | How is RX Switch activated? | Is RX switch handing field reversible? | Can RX switch be added in the field? |
Electrified | L9090EL/EU | Inside lever only | When the inside lever is rotated, the switch is activated thus changing state for the access control system. | Field Reversible | RX Switch can be added in the field |
L9091EL/EU | |||||
L9092EL/EU | |||||
L9093EL/EU | |||||
L9095EL/EU | |||||
L9492EL/EU | |||||
L9493EL/EU | |||||
L9494EL/EU | |||||
L9495EL/EU | |||||
Electrified Vandlgard | LV9090EL/EU | Both inside and outside levers | When the inside or outside lever is rotated, the switch is activated thus changing state for the access control system. | Not Field Reversible | Complete lock case has to be replaced to add RX |
LV9091EL/EU | |||||
LV9092EL/EU | |||||
LV9093EL/EU | |||||
LV9095EL/EU | |||||
LV9492EL/EU | |||||
LV9493EL/EU | |||||
LV9494EL/EU | |||||
LV9495EL/EU | |||||
Discontinued Electrified | L9080EL/EU | Both inside and outside levers | When the inside or outside lever is rotated, the switch is activated thus changing state for the access control system. | Not Field Reversible | Replace with L9092 lock case with RX |
L9082EL/EU | Replace with L9095 lock case with RX |
INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.
YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.