How does the B611 function?

The Falcon B611 is a dormitory/corridor function lock.  

Function description: Deadlocking latch bolt by levers except when locked by push button on inside lever. Key in outside lever locks or unlocks outside lever and releases button. Closing door releases push button.  Inside lever is always free.

Function details:

If push button is used to lock the outside lever, then any of the following will cause the button to pop out and the outside lever to unlock:

  • Rotating the inside lever
  • Closing the door
  • Using the key in the outside lever

IMPORTANT If key is used to lock the outside lever, the push button remains “popped out” even though the outside lever is locked.  In this case, the outside lever can only be unlocked by using the key in the outside lever.  

Neither rotating the inside lever or closing the door will cause the outside lever to unlock when locked by key.  

 