How do you wire the 8310-865 receiver to a 4600 Series operator?

The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.

The 8310-865 RF Receiver has a 4 wire cable (Red, Black, White, Green).

4600 Operator Connection:

Hardwired

  • Normally Open connects to Terminal 16
  • Common connects to Terminal 17.

Wireless - using the 8310-865 receiver

  • Red wire connects to Terminal 1.
  • Black wire connects to Terminal 2
  • White wire connects to Terminal 16
  • Green wire connects to Terminal 17.

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.