The 8310-865 RF Receiver is shipped with a 4 wire cable (Red, Black, White, Green).
The LCN 2800/9500 Series operator comes with 2 Activation Cable connections (Cable 761464 – P6/P7 cable) – This cable can be wired directly into the receiver terminal block as shown in the 8310-865 instructions, see here.
You can also wire the P6/P7 cable to the wires included in the receiver, but this will give you approx. 7’ total of wire. The connections would be as follows: