Remove the PIM400/401 cover. Connect the HHD to the PIM using the HH-USB cable. The PIM400/401 will be displayed on the HHD screen. On the HHD, select Device Options, On the PIM400/401, press and hold the LINK 1 button. Then press the LINK 2 button three times. On the HHD, select Couple HHD to Device. When Coupling is successful, a message will be displayed on the HHD screen.
You can also follow the proper procedure by linking to the Schlage Utility Software User Guide document on page 19 Couple HHD to PIM.
If the PIM400 has already been coupled with a HHD, the Coupling process will be disabled and the PIM400 will no longer go into its Coupling Mode. You must RESET the PIM400 in order to allow (re-enable) coupling of the PIM400.