XceedID 37 bit conversion example
Sample hex data: 82DB2710
Convert the diagnostic data from hex to binary (use the Windows calculator as opposed to the Proxilator utility)
10000010110110010011100010000
Parity bit 16 bits are Facility code 15 bits are BID/hotstamp 4 padding Parity bit
1 0000010110110110 010011100010000 0000 0
1462 10000
XceedID 26 bit conversion example
Sample hex data: 8F16B3C0
Convert the diagnostic data from hex to binary (use the Windows calculator as opposed to the Proxilator utility).
10001111000101101011001111000000
Remove the last 6 bits creating a 26 bit number.
10001111000101101011001111
Parity bit 8bits are Facility code 16 bits are BID/hotstamp Parity bit
1 00011110 0010110101100111 1
This entry is not exhaustive and more information is to be added.
The development of a small software application is currently being considered for this conversion process.
Updates will follow.