The "common" of all the actuator switches will connect to terminal 10. The N.O. (normally open contact) will connect to Terminal 5, 6, 7 or 8 depending on which control box is used and the function required.
Terminal 5 = "B" Sequence Input
Terminal 6 = "B" Only Input
Terminal 7 = "A" Sequence Input
Terminal 8 = "A" Only Input
Terminal 10 = Common to all actuators