Enabling the Schlage RC (RC11, RC15, RCK15) Lock On Close (aka Anti-Tailgate) Function

The Schlage RC’s Blue wire (Door Position Switch Input), when connected to the Black wire (Signal common/dc ground), can be used to monitor the physical Open/Closed state of an access point, and is part of the Lock On Close logic.
Note: Door Position Switch is REQUIRED to be installed and activated for Lock On Close to function.


What is “Lock on Close”?
Lock On Close is also known as an “Anti-Tailgate” function.  If a user with a valid credential were to unlock the door, and the door were to close, then the door will relock immediately.  This will relock the door even if unlock time were remaining.


In order to enable this function for the Access Point in Pure Access Cloud (PAC):
1)    Click on the Access Points (Door Icon) on the left side of the screen.
2)    Find the Access Point in the list.
3)    Click on the three dots to the far right of that access point’s row.
4)    Select “Edit Device Settings”
5)    Ensure “Door Sense” is already enabled and configured properly.
6)    Click the “Lock On Close” slider to enable it, it will turn green.
7)    Click “Next” and then save the selections.
 

More information can be found in the Pure Access Cloud manual here.