The Schlage RC’s Blue wire (Door Position Switch Input), when connected to the Black wire (Signal common/dc ground), can be used to monitor the physical Open/Closed state of an access point.
In order to enable this function for the Access Point in Pure Access Cloud (PAC):
1. Click on the Access Points (Door Icon) on the left side of the screen.
2. Find the Access Point in the list.
3. Click on the three dots to the far right of that access point’s row.
4. Select “Edit Device Settings”
5. Click the “Door Sense” slider to enable it, it will turn green.
6. In the new “Door Sense Input Type” dropdown that displays, select either “Normally Closed (aka active high)” or
“Normally Open (aka active low)” depending on the type of switch being used as a trigger. Note: “Normal” state
is when the door is CLOSED.
7. Click “Next” and then save the selections.
More information can be found in the Pure Access Cloud manual here.