Do I have to use the 388 to get NL-OP on a 33A/35A series device?

The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.

The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.

The 33A/35A devices project into the door by ½" and the screw used to secure the 110NL is located in the same place as the housing projecting into the door. As such, these two products are incompatible.