CO / AD will not lock but proper LED indications are displayed for validated unlock

Check the key operation Rotate counter clock wise  or clock wise, 120 degrees rotation should be observed for latch retraction in either direction. If the points of latch retraction are grossly assymetrical the tail piece is incorrect. Remove Lever and check tail piece orientation