Can the low coin cell Nuisance delay be Disabled on a CO200?

The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.

Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.

If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)
The coin cell Nuisance Delay will be "Automatically" re-enabled after a Door file is successfully downloaded to the CO lock or whenever the feature is specifically re-enabled using the SUS application.

The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.

The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.