Can the Gen2 indicator be ordered with an electrified L9000 mortise lock?

Non-Deadbolt functions: (L/LV9090, L/LV9091, L/LV9092, L/LV9093, L/LV9094, L/LV9095) not allowed due to these locks not having a turn hub.

Deadbolt functions: (L/LV9492, L/LV9493, L/LV9494, L/LV9495) can be used with an indicator but will display an incorrect lock state depending on operation, see notes below.

L9492 & L9494:

False indicator readings: If deadbolt is retracted but lever is locked, the indicator would show “unlocked”- giving a false reading. If the lever is unlocked, but the deadbolt is extended, you can still simultaneously retract from the outside even if the indicator says “locked”- again giving a false reading. 

L9493 & L9495:

False indicator readings: These functions require a single spindle through the chassis. If deadbolt is retracted but lever is locked, the indicator would show “unlocked”- giving a false reading. If the lever is unlocked, but the deadbolt is extended, you can still simultaneously retract from the outside even if the indicator says “locked”- again giving a false reading.