Can the 98/9947WDC or 98/9950WDC device be paired with a 98/9975 mortise lock device?

The 98/9975 exit device requires a strike to be mounted to locking edge of the other door leaf in a paired opening. 

It is not possible to mount a strike on the door with a 98/9947WDC or 98/9950WDC because these concealed rod and cable devices have an opening in the same location the 98/9975 strike would mount.  This opening allows access to rod or cable components inside the door and is covered by a metal plate once installation is complete.

It is suggested that a pair of concealed rod/cable devices should be used instead.