Can the 252L be ordered in an NL storeroom function?

The 252L is only available in L (classroom) or L-BE (passage) functions and cannot be converted or setup for a Nightlatch (L-NL) function.
This device and trim was designed for a specific code application that requires the trim on a pool enclosure be located at 54" if the trim is not automatically locked.  Meanwhile, the Exit Device still needs to be mounted at a lower height (16" - 18" below the lever).

If a Nighlatch (NL) function is desired with the 98/9952 Pool Gate Device, order the 98/9952 Pool Gate Device as EO (Exit Only), then order a standard 98/99 Series NL Trim for Rim/Vertical devices  (990NL-R/V or 996L-NL-R/V) on a separate line to be installed together in the field.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.