Can I use a L9000 Gen1 or Gen2 sectional indicator with hospital push pull paddles?

You cannot order the HL6-9000 with a Gen2 indicator or 09-611 Chevron style indicator. 

Exception: the HL6-9486 by default ships with the 09-611 Chevron style indicator.



When using sectional Gen2 indicators ordered separately:

  • The Gen2 sectional indicators indicators can be paired with the HL6-9000 lock, but the paddles must be mounted horizontally.
  • The difficulties with Gen1 indicator install when using HL6-9000 paddles are resolved with the Gen2 indicators.  
  • Click here for installation instructions for the Gen2 sectional indicator. 

There are challenges that must be overcome when trying to use the Gen1 indicator (discontinued) with the HL6-9000.  (See image below on left):

  • The push/pull paddles will have to be mounted horizontally
  • The L9000 emergency(privacy) and cointurn indicator rose has a trim screw located on the bottom that will be difficult to install with the paddle cover in place
  • the HL6-9000 cover has a trim screw directly below the indicator that will be difficult to install with the L9000 indicator in place

When using 09-611 Chevron style indicator (Image below on right):

  • The 09-611 Chevron style indicator can be paired with the HL6-9000 lock, but the paddles must be mounted horizontally.  





DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.