Can I order ANSI / ASA strikes with Interconnected locks?

The Schlage CS210 or S200 series interconnected locks are not available with ANSI/ASA strikes.

The Falcon H2000 series (H2101, H2171) are not available with an ANSI strikes.

 


You can order the 10-025 ANSI latch strike or the 10-087 ANSI deadbolt strike separately. However, when using a ANSI/ASA strike with an interconnect lock, there are things that must be considered:

  • You cannot use a ASA/ANSI latch strike and a ASA/ANSI deadbolt strike (like the 10-087) on a 4” CTC (latch to deadbolt)
  • Schlage does not have door prep templates for the use of ANSI strikes on interconnect locks

 



The CS210, H2101 and H2171 interconnect locks have not be tested or certified with ANSI/ASA strikes, therefore the use of ANSI/ASA strikes with the lock would invalidate any UL rating and warranty for the locks.