FOR TESTING PURPOSES ONLY
The following wiring can be used to verify that the device will arm and alarm.
The FA Connection (a Normally Closed Fire Alarm Dry Contact between the Yellow and Red wires of the main Chexit cable) is required to meet applicable codes.
Therefore, do not leave the device wired as described below after testing.
Red and Black to power. Red is DC+
For bench testing: Tie Orange, Yellow, and Green wires to the Red (DC+ / Common)
After testing that the device will arm and alarm, follow the applicable wiring diagram in the Installation Instructions.
Reference