CT5000 / WRI400 has two reader interface inputs/outputs. The connections are labeled READER1 and READER2,
The CT5000 / WRI400 with two READERS has access rights for one door opening.
The CT5000 / WRI400 has signal lines for each reader - CLK\D1, DATA\DO, GND, BEEPER, GRN (led), RED (led),
CT5000 / WRI400 can control access for one opening that might need two readers, such as the following applications;
1) A door frame reader(1) and a post (ADA) reader (2)
2) As two readers with one on left side READER (1) and one on the right side READER (1) of the opening,
3) The same opening with two readers, one as an outside reader (1) and the other as an inside reader (2).
Note- The CT 5000 / WRI400 will not power the readers; the interface is a signal interface, not a power interface.
The readers are effectively parallel and will be seen as one reader by the system.