Plant-ons made of wood, metal or other non-combustible material may be applied to one or both faces of doors with a maximum hourly fire rating of three hours. Trim, molding, and plant-ons do not include wood veneer. Wood veneer may not be applied to Steelcraft fire doors. Trim and molding may have a minimum thickness of 1/8” and a maximum thickness of 1-1/4”. Trim, molding and plant-ons may not be attached to the door with mechanical means. The only approved attachment method is to use the double-faced tape specified. Acceptable tapes are:
3M # 969, 3M # 950, and 3M # 444.