Addressing AD400 - PIM400-485 in a Sielox system

Sielox has an internal software door indexing range of  3-34.
To address AD400s the logical door selection for linking cannot be any lower than 3 and should match in the Sielox system. No offset as in some other systems.
Addressing still covers 16 Logical doors per PIM. To Achieve the full range allowed by the Sielox system each subsequent PIM must have unique RS 485 address and the LOW HIGH door range addressing must be adjusted to next unique 16 door range not to exceed address 34 at the top of the Sielox panel range. See example below.

PIM  addr / logical door LOW HIGH
  
1/ 3-18
2/19-34
  