Adding locks to Legacy PIB-4D- additional locks not recognized.

When adding another door to the legacy PIB-4d, You must change the S1 dipswitches 11 & 12
Number         Dip11  Dip12    
of locks
1                     -          -
2                     x          -  
3                     -          x 
4                     x          x 
 
PIB power must be cycled to allow reading of the new configuration and recogizing the additional lock.
 