-On the AD series offline locks only you can change the lock function from Classroom/Storeroom to a Privacy, office or apartment function out in the field.
 - This is done via the HHD/SUS using the "Device Options/Lock Properties
 - They will need to make sure that they have the door position switch (DPS) installed in order for PRIVACY and APARTMENT functions to  work correctly and the correct inside cover to support Pressing the IPB with the cover in place.