8310-865 receiver and sequence.

RF sequential operation requires the use of of a minimum of 2 receivers (8310-865). Depending on the desired operation required (if using access control), it may require up to 4 receivers (8310-865).

Programing Steps:

  • Program exterior actuator for "NO DELAY" on receiver for exterior door, and for "DELAY" on receiver for interior door.
  • Program interior actuator for "NO DELAY" on receiver for interior door, and for "DELAY" on receiver for exterior door.
  • Program exterior vestibule actuator for "NO DELAY" on receiver for exterior door only.
  • Program interior vestibule actuator for "NO DELAY" on receiver for interior door only.

Operation:

  • Exterior actuator opens exterior door, then sequences interior door.
  • Interior actuator opens interior door, then sequences exterior door.
  • Exterior vestibule actuator opens exterior door only.
  • Interior vestibule actuator opens interior door only.