SW4-8 Off ( disabled )
Also verify
NUISANCE DELAY (factory default: 3 seconds)
The amount of time the door must be pushed before triggering the DELAYED EGRESS CYCLE
Programmable 0 - 3 seconds. (BOCA Units are fixed at 1 second.)
A. Press and release SW3, the LED will begin flashing RED.
B. Thereafter, press SW2 once for each second of nuisance delay desired, up to 3 seconds maximum.
Each SW2 activation will cause the LED to flash GREEN and the horn to beep .
C. Press SW3 and the nuisance delay will be stored in non-volatile memory.
NOTES: 1. To program nuisance delay to zero, eliminate Step B.
2. Setting nuisance delay to zero will allow the lock to go into delayed egress the instant the door is pushed. This may prove
inconvenient in some applications.