Which door closer should I use in High Wind condition
”
RELATED FAQS
Question
Answer
Which closer should I use for a "High Wind" condition?
Resolution:
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
Does LCN sell a coupler to stack two 4040XP closers together?
Resolution:
LCN does not recommend this type of installation, and has never sold a coupler to do this.:
What is the LCN fluid - "Liquid X" - temperature range?
Resolution:
The LCN closer fluid "Liquid X" will perform without variation between: -30° F to +120° F - for manual closers. +35° F to +120° F - for electrical closers and a...:
Will a 4640 operator open the door in windy conditions?
Resolution:
The 4600 operator is designed to meet the ANSI Code 156.19 that limits the opening force to a 15 lbs. By code and design, the operator must stop opening the door when an obstruction or resistance ...:
What is the delay time adjustment on a Delayed Action closers?
Resolution:
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...:
What special template (ST) is used with the 2030 closer and a low profile track and roller?
Resolution:
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track. For a top rail less than 1-3/8" and as narrow as 1", you could use the l...: