Answer
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...
The following are part numbers for 2670 Guard X exit device PCB: pcb.10018 for English pcb.10019 for Spanish pcb.10020 for French
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike
Replacing the battery on the 2670 should not cause the unit stop working. Make sure the spring that provides tension on the plastic finger is not bent out. The spring should be at a 90 degrees...
The RGO (rod guard only) is 36" long x 1-5/8" wide.
The 2670 Guard X device can't be cut down to fit doors less than 3 feet.  This device is designed to fit doors 36"-48" door width.
The 2670 Guard X uses a standard rim cylinder for either push side or pull side.  The rim cylinder can be installed to the outside of the opening with an offset pull to operate the 2670 Guard X d...
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.