steelcraft tech data book

RELATED FAQS

Question
Answer
A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...
All read ranges are affected by the environment the reader and card are subjected too.  The following data was obtained in a relatively "noisy" RF area with the reader mounted on a metal ...
All read ranges are affected by the environment the reader and card are subjected too.  The following data was obtained in a relatively "noisy" RF area with the reader mounted on a metal ...
The minimum stile and rail dimensions with glass trim are as follow: Top Rail: 6 1/4" top of door to exposed glass or 5 1/2" top of door to cutout Center Rail: 6 1/2" exposed gla...
Hospital Stops are located at the bottom of the frame jambs and/or mullions. The integral door stops are terminates above floor line and is closed with a 45° or 90° angle to facilitate cleaning at ...
Communicating Frames are hollow metal frame fabricated such that a door is installed in each rabbet of a double rabbeted frame (2 doors total) to facilitate dual access and control of the opening, ...
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as assemblies wit...
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the he...
The standard gap between a pair of doors will be 3/16" when used with a Steelcraft  "Z" astragal. If a wide inactive leaf is requested (no astragal) the gap between the doors will be...
A Dutch Door is a door having two separate leaves, hung one over the other: Usually equipped so that both leaves can be operated Usually in single doors applications but sometimes specified ...
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...
Masonry T anchor are approved for fire rated frames up to 3 hours. T Anchors are shipped lose for field installation. Anchor construction: The T portion and the strap do have minimum dimensions th...
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
The minimum stile and rail dimensions are to exposed glass are: Stiles = 6 13/16" Top Rails = 6 3/4" Center Rails = 7 1/2" Bottom Rail = 10 3/4" For high traffic and high abuse locations th...