steelcraft drywall frame installation instructions

RELATED FAQS

Question
Answer
Drywall Throat Fillers are used when wall thickness is between 1/8” (3mm) to 1/4” (6mm) less than the frame throat dimension, throat filler section(s) can be used to fill the gap, assuring the prop...
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
This condition (toed in or toed out jambs) is usually not found until the door is installed. Frames which have toed in or toed out jambs have been installed out of tolerance. It is the resp...
Both the DW and K-Series frames are identical with the exception of the base anchoring. Both the DW and K-series frames are supplied with a field adjustable compression anchor in each jamb located ...
Drywall Slip-on Frame is an industry term describing a 3 sided frame designed to be installed on a wall composed of steel or wood studs with gypsum board or other facing material and is i...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
Out of plumb (also referred to as twisted) frames usually cannot be adjusted. "Out of Plumb or Twisted frames (or jambs)" is a condition created by improper wall construction and/or improper insta...
It is the responsibility of the installing contractor to install all material in accordance with SDI or HMMA installation standards and tolerances. Out of square frames which are installed out of t...