Question
Answer
Can you add SD and EL to a mechanical 99 series exit device?
Resolution:
This is available. You will need the SD center case kit, SD center case cover, SD cylinder dog housing, and EL/QEL conversion kit.:
What is the part number for the HD EL conversion kit for Von Duprin devices?
Resolution:
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.:
What is the part number for hex dogging conversion kit for a 99 device?
Resolution:
The part number for hex dogging conversion kit for 99 devices is 050114.:
What is the part number for QEL94/95 inpact conversion kit?
Resolution:
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required: Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...:
Is there an EL conversion kit for the Falcon 2390 exit device?
Resolution:
There is no EL conversion kit for a 2390, the device will need to be replaced.:
Can you cut the EL conversion kit - 3' base plate to fit a 30" 9947 device?
Resolution:
You need to order the EL98/9947 or 3' EL conversion kit. This will fit on 28 1/8" minimum door opening on two vertical x vertical rod device doors.: