RX-LC for falcon
”
RELATED FAQS
Question
Answer
Can you field install a RX switch on the 24/25 device?
Resolution:
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...:
What is the difference between an RX switch and an RX-LC (low current) switch?
Resolution:
The standard Von Duprin switches (RX and LX switches in exit devices, and DS dual switches in 6100 and 6200 Electric Strikes) are rated for 0.05A to 2A @ 24 VDC. The low curren...:
Why does the AD300-993 and AD400-993 require Von Duprin RX-LC switch
Resolution:
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units. A low current switch is needed because … - &nb...:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed:
Is the RX option the same as the old AE option on Falcon exits?
Resolution:
The AE option is now called RX (Request to Exit) to match other Allegion exit brands nomenclature. The feature of getting a signal from the pushing of the device's pushpad is the same. :
Does the Falcon T series have an RX option available?
Resolution:
The Falcon T Series lock does not have an RX switch available.:
Can the Von Duprin RX Switch be installed on an existing Falcon Monarch 19?
Resolution:
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.: