rim wont open

RELATED FAQS

Question
Answer
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
The NL key override will not open the door while Chexit rim or vertical rod device is in the arm mode.
The existing 373L control was modified and re-named as 379L to allow us to use the 55 rim device on an ADA door opening.  The 379L control is our 373L with different hex st...
Chexit devices are NOT electric latch retraction.  In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...
4754, 4854 and the 9854 are electrified mullions and handed as noted below: 4754 is not handed: Prepared for two 4263 monitor strikes. Use with all Von Duprin rim panic devices 4854 is han...
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
Position the 379L  trim and attach with countersunk screw into the bottom stud of the trim.  Position the 55 Rim device and attach with the device mounting screw through the head of th...