Question
Answer
Applies only to Von Duprin QEL exit devices shipped after December 11th, 2014.1.0 amp inrush and a 0.14 amp holding current.
The following could cause the QEL device to retract and release repeatedly: If this is a vertical rod type device, the vertical rods could be adjusted too short. Check rods for dead locking, ...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...
Improper mechanical adjustment or QEL calibration could cause the QEL cycle three times with solid LED and not work. First check mechanical adjustment on vertical rods or mortise lock device and co...
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used. ...