push side frame reveal

RELATED FAQS

Question
Answer
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
Reveal is the distance or measurement from the face of the door out to the face of the frame on the push side of the door.Other related terms:Door face - The exposed surface of door visible wh...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
An LCN 4040T with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE)arm. ST3073 Standard 4040T DE Arm will accommodate reveals up to 2-11/16"....
Track Style, Double Egress Mount
The following size limitations per frame unit, are in enforced for welded elevation frames shipped from the factory. These limitations are in place due to the physical size of shipping tr...
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...
Yes. 1 7/16" thick glass but a special rabbet size is required. The size of rabbet required for the frames would depend on the size of the glazing bead being used. For 1" wide glazing stops, ...
NO - Louvers are not approved for installation in a fire rated transom / side panel frames.  NFPA Pamphlet 80 - paragraph # 6.3.4.4 states “Louvers shall not be installed in either transom or s...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...