mullion with recessed strikes
”
RELATED FAQS
Question
Answer
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
What electric strikes can be used with the Von Duprin aluminum mullions?
Resolution:
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike.:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...: