Make closure with more pressure
”
RELATED FAQS
Question
Answer
Does LCN sell a coupler to stack two 4040XP closers together?
Resolution:
LCN does not recommend this type of installation, and has never sold a coupler to do this.:
What door meets FBC / NOA Zone 4 requirements?
Resolution:
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements?3070 max flushOutswing & Inswing applicationsZone 4 requires 120 to 170 psf.:
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
What is UBC 7-2?
Resolution:
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...:
How do you remove an AL lock from a door?
Resolution:
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...: