INSTRUCTIONS FOR ALK
”
RELATED FAQS
Question
Answer
Where can I find templates for the 237L two point latch device?
Resolution:
Click HERE for the instruction and template for 237L device.:
Is there an Exit Alarm Retrofit Kit (EAK) for the 19 series?
Resolution:
These kits for the 19 Series were discontinued June 11th, 2012 when the updated alarm kit for the 24/25 series was released. Prior to discontinuation, it was o...:
Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...:
Can the Von Duprin Chexit device be changed to ALK exit alarm?
Resolution:
The Chexit device has a different base plate and center case than the ALK. The Chexit device would need to be replaced with an ALK device.:
What is different about the updated Falcon Exit Alarm (EA) option ?
Resolution:
The Falcon Exit Alarm option was updated in June 2012 to include the following benefits. Louder Alarm 95dbs vs 87dbs Easier battery changes 24Vdc hardwire(HW) option included w...:
What could cause the Von Duprin exit alarm ALK to turn off after one or two minutes?
Resolution:
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...:
Does Von Duprin offer a water proof ALK?
Resolution:
Exit alarm ALK devices are not recommended for exterior application. We do not offer water proof exit alarm ALK devices.:
Were the ALK PCB boards blue at one time?
Resolution:
No, the exit alarm ALK printed circuit board has been always green.:
Will the PT790 work with the ALK?
Resolution:
The new exit alarm ALK uses the 24VDC regulated PS902 power supply.:
Can the green terminal block be soldered back on if it has broken off the ALK board?
Resolution:
If the green terminal block has been broken off of the exit alarm ALK you must replace the exit alarm ALK PC board part number 101030-00.:
What is the part number for the ALK sign?
Resolution:
The sign for exit alarm, ALK, is SIGN-1.: