head jamb mounted electric strike for SVR exit device
”
RELATED FAQS
Question
Answer
Does the Von Duprin 6121 electric strike work with the Von Duprin XP exit device?
Resolution:
Von Duprin does not recommend using XP98/99 devices with any electric strike. Von Duprin recommends using the standard 98/99 rim device. :
Is the Von Duprin 6111 electric strike compatible with Von Duprin XP98/99 rim exit device?
Resolution:
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. Typically the XP device will withstand a higher force than electr...:
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
Will the 6300 work with the 55 rim?
Resolution:
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.:
Can you use the 6300 with the 33A/35A device?
Resolution:
You can use the surface mounted 6300 electric strike with 33A/35A rim exit device as long as you have enough stile width for this strike.:
What electric strikes can be used with the Von Duprin aluminum mullions?
Resolution:
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike.:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...: