falcon narrow exit device electrical retraction

RELATED FAQS

Question
Answer
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
There is no EL conversion kit for a 2390, the device will need to be replaced.
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.&n...
Electric Latch Retraction(ELR) option for the 19 Series was discontinued in December of 2006.
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...
 The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device.  The 718C trim is listed in the Price Book for the 25 series  The instructions attache...
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
Falcon (19. 24, 25, and XX) parts manuals for Exits are downloadable on the 
Falcon 25 series is a ANSI/BHMA A156.3 Standard for Grade 1 device.
Falcon F-25 series is the UL Rated Fire Exit Hardware device is a ANSI/BHMA A156.3 Standard for Grade 1 device.
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA
Falcon Monarch 24 series exit devices replaced the 17 Series exit devices. Falcon Monarch 25 series exit devices replaced the 18 Series exit devices.
The part number for 1690/1790 hex dogging shaft is shaft.101
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-25 Series can perform a delayed egress by using the DE5300 controller, power supply, ...
The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device.
Please contact the Allegion Product Support Team on all questions or inquiries pertaining to hardware finishes warranties. Please send an e-mail to the applicable Product Support team:Closers_TechP...
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
For any device made after 2001, the part number for the Falcon 1690 dogging kit would be KIT.1197 For devices made prior 2001, the dogging kit is no longer available and a new device must be ...
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
The Von Duprin Pneumatic PN98/99 series exit devices feature provides remote latch bolt retraction in hazardous areas where electrically operated devices would not be permitted.
The Von Duprin Pneumatic or "PN" device was designed for Intrinsically Safe Class 1, Division 1 applications.
 HD-EL (Hex Dogging Electric Latch Retraction) solenoid and plunger can be replaced with standard EL solenoid and plunger on non fire rated exit devices, but this should not be used on a daily basi...
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...
 Electric latch retraction, EL, devices are only available in 24VDC.
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the ...
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from pow...
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
55 and 88 are both crossbar exit devices.  55 Series is used on narrow stile applications, 88 is for wider stile applications. See attached tables for 55 and 88 series minimum stile requirement...
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003).  At one time, the obsolete black EL ...
The standard Falcon 25V vertical rod cannot be cut to fit on a 2 feet door opening.This device requires 2' 7 1/8" minimum door opening. Falcon offers a device that can be used on a 2 feet door...
EL is Electric latch retraction and retract the latch bolt into the exit device center case.  E references the electric unlocking of the Pull Side trim for a Panic Device.   With the E function, th...
Application is based on how the door will be used.   Please contact Product Support at 877-671-7011 to discuss your application and select the correct device for your opening.