falcon exit alarm

RELATED FAQS

Question
Answer
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
The Falcon Exit Alarm option was updated in June 2012 to include the following benefits. Louder Alarm 95dbs vs 87dbs Easier battery changes 24Vdc hardwire(HW) option included w/ standard board...
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst
AR1 is Auto-Reset 1.5 minute, AR3 is 3 minute, or AR6 is 6 minute option processed through engineering specials on a Von Duprin exit alarm ALK.
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.
The standard exit alarm ALK devices are not available with dogging option. The device can be ordered through Engineering Special with dogging option on non fire exit devices. This special is o...