The Von Duprin XP98/99 device uses a different strike than standard 98/99 device.
The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device.
49/9954 mul...
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame. Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.
L, B, CE, T and CE-Series doors are available factory prepared
Door...
The following application information apply to the 5100 electric strike:
Can only be used on a single door with a cylindrical lock
Can not be used on a pair of doors
Can not be used on a mullion
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
The backset is 2 3/4" from edge of door to the center line of the device and strike.
The preparation for the WS98/99 strike must be specified when placing order for the frame.