el coil test
”
RELATED FAQS
Question
Answer
What is the best way to test the Von Duprin EL solenoid?
Resolution:
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...:
How do you test a Falcon 24 or 25 Series EL solenoid?
Resolution:
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...:
Why does the DC output voltage on the PS914-2RS or PS914-4RL drops when access control is activated?
Resolution:
Following items could cause the DC output on PS914 series power supply to drop when access control is activated. Wrong gauge wire from power supply to the the power transfer. Excessive wire run...:
Why do you need the potted circuit breaker for the Von Duprin EL device?
Resolution:
The potted circuit breaker for the Von Duprin EL device does the switching from the 16 amp pull coil on the solenoid to the .33 amp holding coil of the solenoid.:
Why would an EL 98/99 solenoid get hot?
Resolution:
If voltage going into the solenoid is much higher than 24VDC it could cause the solenoid to get hot. Check the power supply output voltage to confirm. If the holding coil on EL solenoid is shor...:
What could cause the fuse to blow in a PS873 power supply?
Resolution:
Following could cause the fuse to blow in Von Duprin PS873 power supply. PS873 power supply provides 2AMP at 24VDC or 4AMP at 12VDC. If this limit is exceeded the fuse will blow in the power sup...:
Can I bypass the circuit board on a M420 M450 or M490: Unsupported voids warranty
Resolution:
No the M400 series of mag locks may not operate direct wiring the power to the coils . Bypassing the circuit board or direct wiring the coils is not supported and voids the warranty ...:
Can the low coin cell Nuisance delay be Disabled on a CO200?
Resolution:
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.: