The Minimum single door opening should be 26.32" and use the 299 or 499F strike.
The Von Duprin CX 98/99-4 feet Rim devices on single doors with 5/8" stops and the standard 299 roller strike can be field sized to fit a minimum of 40.2" door opening.  This an...
A Door Position Switch is a switch and magnet mounted on the door and frame that monitors the door status. If door is held open beyond rearm time or if door is forced open, alarm wil...
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
Chexit devices are NOT electric latch retraction.  In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.