For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
No, the geometry of a swing clear hinge prevents the coordinator from working correctly.  The bar style coordinator will not hold the active door open far enough for the inactive door to clear the ...
Allegion does provides professional support to Architects and Design Professionals. For information related to specification development and support, Website for Architects and Design Professiona...
Allegion provides professional access control support to Security Consultants and Security Integrators.  For information related to specification development and support,Access Contro...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. 
The Date Code and Closer Size are stamped in the backside of the closer body. Closer Size: If the number is "1", the closer is a 2031 or 5031. If the number is "3", the closer is a 2...
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
2030 and 5030 are both overhead concealed closers. The 2030 uses a concealed, in the door, track, and a concealed one piece arm. The 5030 uses a exposed double lever arm (like the arm for a 401...
The Dor-O-Matic overhead concealed manual door closers have been obsolete since 1999, and there are no parts available for them.
There are 2 types of door coordinators available: Bar Coordinators (Ives COR Series): Surface mounted to the bottom surface of the frame soffit. The active door lever, located nearest to th...
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 d...
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
LCN does not recommend this type of installation, and has never sold a coupler to do this.
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
14" door leaf is the narrowest with standard template.
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AND SHOE: ...
Locate closer and arm from the centerline of the swing clear hinge pin.
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detectors ...
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit  There is no closer that can replace the old 4030 series closer with the exa...
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.
A designer series metal cover is an option with the 1460 series closer, the part number is, 1460-72DS1.
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
The 4330 / 4430 is an obsolete ME closer replaced by the 4310ME or 4410ME Series.
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. 
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. 
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops.  The exception is:  the 4041/4040XP mounted on a drop plate, and the Glynn Jo...
All LCN closers have UL listings, and are Fire Rated for up to 3 hours.
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates. The 4110 if ordered by ST-3220 will allow templating to 135°
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
The part number is: 1461-3071 for the door closer cylinder body.
The measurements from center line to centerline of the mounting holes are 2-3/8"  x  6-3/4".