ARCHED HEAD DOOR DROP PLATE

RELATED FAQS

Question
Answer
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...
The 4110-18, and 4110-18 CUSH  drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate.  If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 d...
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...
Top Rail, Narrow Top Rail, Narrow Face Frame, Flush Ceiling